Sign In | Join Free | My uabig.com
China Britec Electric Co., Ltd. logo
Britec Electric Co., Ltd.
Britec Electric Co., Ltd.
Verified Supplier

8 Years

Home > Type 2 Surge Protection Device >

BR-60 3P+1 T2 Type 2 Surge Arrester Lightning Thunder Protector Spd surge Device

Britec Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

BR-60 3P+1 T2 Type 2 Surge Arrester Lightning Thunder Protector Spd surge Device

Brand Name : BRITEC

Model Number : BR-60 3P+1

Certification : TUV/UL/CB/CE/ROHS

Place of Origin : China

MOQ : 10 Piece/Pieces

Payment Terms : L/C, D/A, T/T, Western Union

Supply Ability : 50000 Piece/Pieces Month

Delivery Time : Shipped in 15 days after payment

Packaging Details : EXPORT PACKING

Item Name : Type 2 surge arrester

Model Numbers : BR-60 3P+1

Customized : Yes

Protection Class : IP20

Color : white

MOQ : 1PCS

Mounting Type : DIN rail: 35 mm

Response time : ≤25 ns

Number of ports : 3p+1

Contact Now

3+1 surge protection device spd manufacture Type 2 surge arrester

We can produce according to your requirements.

Contact us get the lowest price

Type 2: These SPDs are meant for installation within the main distribution board of residential and commercial establishments. Best suited for protection against switching transients and indirect lightning, characterized by an 8/20 μs current wave. Combines Type-1 and Type-2 devices are also available in the market. Type 2 devices usually use metal oxide varistor technology.

Other type for choose:

1,Maximum discharge current:10kA,20kA,40kA,65kA,80kA,100kA,120kA

2,Number of poles:1P,1P+N ,2P,3P,3P+N, 4P

3,Maximum continuous operating voltage: 275V,320V,385V ,440V,550V

Type 2 surge arrester Technology characteristic:

BR-60 3P+1 T2 Type 2 Surge Arrester Lightning Thunder Protector Spd surge Device

BR-60 3P+1 T2 Type 2 Surge Arrester Lightning Thunder Protector Spd surge Device

BR-60 3P+1 T2 Type 2 Surge Arrester Lightning Thunder Protector Spd surge Device

BR-60 3P+1
Max. continuous operating a.c. voltage Uc(L-N/N-PE) 275V/255V (50/60Hz)
Nominal discharge current (8/20us) In(L-N/N-PE) 30kA/30kA
Maximum discharge current (8/20us) Imax(L-N/N-PE) 60kA/60kA
Voltage protection level Up(L-N/N-PE) ≤1.6kV/≤1.5kV
Response time tA ≤25ns
Max. backup fuse 125A
Operating temperature range Tu -40℃—80℃
Cross-section area (Min.) 4mm2
Cross-section area (Max.) 35mm2
For mounting on 35mm Din rail
Enclosure material Thermoplastic UL94-V0
Test standards

IEC 61643-11, EN 61643-11


Type 2 surge arrester Dimension:

BR-60 3P+1 T2 Type 2 Surge Arrester Lightning Thunder Protector Spd surge Device

Type 2 surge arrester Application:

Application: Grid Power, AC Power Circuit, AC Distribution Box, LT Electrical Panel
AC SPD uses for AC Power or Grid Power to protect against transient ac voltage.

Type 2 surge arrester Certificate:

CB, CE, TUV,RoHS Certificate

BR-60 3P+1 T2 Type 2 Surge Arrester Lightning Thunder Protector Spd surge Device
Company information:

Wenzhou Britec Electric Co., Ltd. established in the year of 2003 and located in Yueqing, Zhejiang, China. Our company specialized in research and development of surge protection devices.The series of surge protection device Type 1 and Type 2 and Type 3, BR PV and SPDs for Data offer the market with a new choice of high quality surge arresters. We have 18 years of experience in the research & development and production of the surge protection field and provide 5 years warranty.
.

BR-60 3P+1 T2 Type 2 Surge Arrester Lightning Thunder Protector Spd surge Device
Production line:
BR-60 3P+1 T2 Type 2 Surge Arrester Lightning Thunder Protector Spd surge Device
BR-60 3P+1 T2 Type 2 Surge Arrester Lightning Thunder Protector Spd surge Device
Laboratory equipment:
BR-60 3P+1 T2 Type 2 Surge Arrester Lightning Thunder Protector Spd surge Device
Shipping:
BR-60 3P+1 T2 Type 2 Surge Arrester Lightning Thunder Protector Spd surge Device
FAQ:

Q1: Selection of surge protector

Al: The grading of the surge protector (commonly known as lightning protection) Is assessed according to the IEC61024 subdivision lightning protection theory, which is installed at the junction of the partition. Technical requirements and functions differ. The first-stage lightning protection device is installed between the 0-1 zone, high for the flow requirement, the minimum requirement of EN 61643-11 / IEC 61643-11 is 25 ka (10/350), and the second and third levels are installed between the 1-2 and 2-3 zones, mainly to suppress the overvoltage.

Q2: Are you a lightning surge protectors factory or lightning surge protectors trading company?

A2: We are a lightning surge protectors manufacturer.

Q3: Warranty and services:

A3:1. Warranty 5 years

2. lightning surge protectors products and accessories have been tested 3 times before ship out.

3. We own the best after-sale service team, if any problem happens, our team will do our best to solve it for you.

Q4: How can I get some lightning surge protectors samples?

A4: We are honored to offer you lightning surge protectors samples, pis contact our staff, and leave detailed contact information, we promise to keep your information confidential.

Q5: Is the sample available and free?

A5: Sample is available, but the sample cost should be payable by you. The cost of the sample will be refunded after further order.


Product Tags:

3P+1 T2 Type 2 Surge Arrester

      

BR-60 Type 2 Surge Arrester

      

Spd Type 2 Surge Arrester Device

      
Wholesale BR-60 3P+1 T2 Type 2 Surge Arrester Lightning Thunder Protector Spd surge Device from china suppliers

BR-60 3P+1 T2 Type 2 Surge Arrester Lightning Thunder Protector Spd surge Device Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Britec Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)