BR-40 4P 40kA Surge Arrester Protection Device 3 Phase thunder protector spd tuv type 2 surge protection device

Britec Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

BR-40 4P 40kA Surge Arrester Protection Device 3 Phase thunder protector spd tuv type 2 surge protection device

Brand Name : BRITEC

Model Number : BR-40 4P

Certification : TUV/CB/CE/ROHS/ISO9001/ISO14001

Place of Origin : China

MOQ : 1 Piece/Pieces

Payment Terms : L/C, D/A, T/T, Western Union

Supply Ability : 50000 Piece/Pieces Month

Delivery Time : Shipped in 15 days after payment

Packaging Details : EXPORT PACKING

Item Name : 4 poles lighting surge

Model Numbers : BR-40 4P

Customized : Yes

Protection level Up : 1.3kV

OEM/ODM : Available

MOQ : 10 PCS

Type : Type 2

Standard : IEC Standard

Response time : 25ns

Contact Now

40kA 4 poles surge arrestor single phase lightning surge protector

We can produce according to your requirements.

Contact us get the lowest price

4 poles surge protect device Features:

1. Three-phase protection for TN-S system

2. Pluggable module, easy for installation and maintenance

3. High discharge capacity, quick response

4. Double thermal disconnection devices, providing more reliable protection

5. Green window will change when fault and also provide remote alarm control at the same time

4 poles surge protect device Technology characteristic:

BR-40 4P 40kA Surge Arrester Protection Device 3 Phase thunder protector spd tuv type 2 surge protection device

BR-40 4P
Max. continuous operating a.c. voltage Uc 275V
Nominal discharge current (8/20us) In 20kA
Maximum discharge current (8/20us) Imax 40kA
Voltage protection level Up ≤1.3kV
Response time tA ≤25ns
Max. backup fuse 125A
Operating temperature range Tu -40℃—80℃
Cross-section area (Min.) 4mm2
Cross-section area (Max.) 35mm2
For mounting on 35mm Din rail
Enclosure material Thermoplastic UL94-V0
Test standards

IEC 61643-11, EN 61643-11


4 poles surge protect device Dimension:

BR-40 4P 40kA Surge Arrester Protection Device 3 Phase thunder protector spd tuv type 2 surge protection device

Other type for choose:

1,Maximum discharge current:20kA,40kA,80kA,100kA,120kA,200kA

2,Number of poles:1P,1P+N ,2P,3P,3P+N, 4P

3,Maximum continuous operating voltage Uc: 150V,275V,320V,385V ,440V,550V,800V,1000V

Our Main Product

Type 1 surge protection device.

Type 2 surge protection device.

Type 1 + Type 2 surge protection device.

Type 3 surge protection device.

Type 2 + Type 3 surge protection device.

DC (pv, solar) surge protection device.

4 poles surge protect device Application:

surge protectors are used to guard sensitive equipments from voltage spike.

4 poles surge protect device Certificate:

CB, CE, TUV,RoHS Certificate:

BR-40 4P 40kA Surge Arrester Protection Device 3 Phase thunder protector spd tuv type 2 surge protection device
Company information:

Wenzhou Britec Electric Co., Ltd. established in the year of 2003 and located in Yueqing, Zhejiang, China. Our company specialized in research and development of surge protection devices.The series of surge protection device Type 1 and Type 2 and Type 3, BR PV and SPDs for Data offer the market with a new choice of high quality surge arresters. We have 18 years of experience in the research & development and production of the surge protection field and provide 5 years warranty.
.

BR-40 4P 40kA Surge Arrester Protection Device 3 Phase thunder protector spd tuv type 2 surge protection device
Production line:
BR-40 4P 40kA Surge Arrester Protection Device 3 Phase thunder protector spd tuv type 2 surge protection device
BR-40 4P 40kA Surge Arrester Protection Device 3 Phase thunder protector spd tuv type 2 surge protection device
Laboratory equipment:
BR-40 4P 40kA Surge Arrester Protection Device 3 Phase thunder protector spd tuv type 2 surge protection device
Shipping:
BR-40 4P 40kA Surge Arrester Protection Device 3 Phase thunder protector spd tuv type 2 surge protection device
FAQ:

Q1: Selection of surge protector

Al: The grading of the surge protector (commonly known as lightning protection) Is assessed according to the IEC61024 subdivision lightning protection theory, which is installed at the junction of the partition. Technical requirements and functions differ. The first-stage lightning protection device is installed between the 0-1 zone, high for the flow requirement, the minimum requirement of EN 61643-11 / IEC 61643-11 is 25 ka (10/350), and the second and third levels are installed between the 1-2 and 2-3 zones, mainly to suppress the overvoltage.

Q2: Are you a lightning surge protectors factory or lightning surge protectors trading company?

A2: We are a lightning surge protectors manufacturer.

Q3: Warranty and services:

A3:1. Warranty 5 years

2. lightning surge protectors products and accessories have been tested 3 times before ship out.

3. We own the best after-sale service team, if any problem happens, our team will do our best to solve it for you.

Q4: How can I get some lightning surge protectors samples?

A4: We are honored to offer you lightning surge protectors samples, pis contact our staff, and leave detailed contact information, we promise to keep your information confidential.

Q5: Is the sample available and free?

A5: Sample is available, but the sample cost should be payable by you. The cost of the sample will be refunded after further order.

Q6: Do you accept customized order?

A6: Yes, we do.


Product Tags:

class 2 surge Arrester protection device

      

4 Pole surge Lightning Arrester

      

Three phase surge Lightning Arrester

      
Wholesale BR-40 4P 40kA Surge Arrester Protection Device 3 Phase thunder protector spd tuv type 2 surge protection device from china suppliers

BR-40 4P 40kA Surge Arrester Protection Device 3 Phase thunder protector spd tuv type 2 surge protection device Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Britec Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)